Installation

Melos Cable Compounds are used in many different types of installation. Highly resistant cable components are needed in households, in urban applications and in industry. We supply the products!
Melos Cable Compounds are used in many different types of installation. Highly resistant cable components are needed in households, in urban applications and in industry. We supply the products!

Cable Compounds for Installation

Melos code
PDF
Operating temperature [°C]
Tensile strength [N/mm2]
Shore hardness
Elongation at break [%]
LOI [%]
Density [g/cm³]
Oil resistance level
Features
Standards
Applications
Mecoline
I RDX 1260 F
1260
Halogen-free
RDX
Insulation
Flame-retardant
-40 to 125
9
37
D
176
33
1.41
★★★
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
VDE 0207 Part 21 Type E15
VDE 0207 Part 21 Type E15
Installation
Installation
Installation
Mecoline
IS RDX 1263 F
1263
Halogen-free
RDX
Insulation, Sheathing
Flame-retardant
-40 to 120
12
43
D
150
31
1.37
★★
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
EN 50264-1 EI105 & EI110, EN 50363 EI5, EN 50363 EI8
EN 50264-1 EI105 & EI110, EN 50363 EI5, EN 50363 EI8
Installation
Installation
Installation
Mecoline
IS TP 1031 F
1031
Halogen-free
TP
Insulation, Sheathing
Flame-retardant
-30 to 80
10.8
48
D
226
42
1.48
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, DIN EN 50525-3-11 TM7, EN 50363-7 TI6, EN 50363-7 TI7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, DIN EN 50525-3-11 TM7, EN 50363-7 TI6, EN 50363-7 TI7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
Installation
Installation
Installation
Offshore/Shipbuilding
Offshore/Shipbuilding
Offshore/Shipbuilding
Mecoline
IS TP 1032 F
1032
Halogen-free
TP
Insulation, Sheathing
Flame-retardant
-30 to 90
10.5
52
D
196
38
1.49
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 2, BS 7655 part 6.1 LTS 3, BS 7655 part 6.1 LTS4, CEI 20-11 M1, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4, IEC 60092-360 SHF1
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 2, BS 7655 part 6.1 LTS 3, BS 7655 part 6.1 LTS4, CEI 20-11 M1, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4, IEC 60092-360 SHF1
Installation
Installation
Installation
Offshore/Shipbuilding
Offshore/Shipbuilding
Offshore/Shipbuilding
Mecoline
IS TP 1033 F
1033
Halogen-free
TP
Insulation, Sheathing
Flame-retardant
-25 to 90
13
53
D
185
39
1.51
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
Weather resistant
Weather resistant
Weather resistant
VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4
VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4
Installation
Installation
Installation
Mecoline
IS TP 1035 F
1035
Halogen-free
TP
Insulation, Sheathing
Flame-retardant
-30 to 90
12.5
50
D
190
45
1.47
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 6724, BS 7655 part 6.1 LTS 2, DIN EN 50525-3-11 TI6, DIN EN 50525-3-11 TM7, EN 50363-7 TI6, EN 50363-7 TI7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4, IEC 60092-360 SHF1
BS 6724, BS 7655 part 6.1 LTS 2, DIN EN 50525-3-11 TI6, DIN EN 50525-3-11 TM7, EN 50363-7 TI6, EN 50363-7 TI7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4, IEC 60092-360 SHF1
Installation
Installation
Installation
Offshore/Shipbuilding
Offshore/Shipbuilding
Offshore/Shipbuilding
Mecoline
S TP 1006 F
1006
Halogen-free
TP
Sheathing
Flame retardant
-25 to 90
10.3
50
D
179
45
1.56
★★
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 6724; BS 7655 section 6.1 LTS 2; CEI 20-11 M1; DIN EN 50363-8 TM7; DIN VDE 0276-604 HM4; DIN EN 50525-3-11 TM7; IEC 60092-360 SHF 1; NF C 32-323; VDE 0207 part 24 HM 2, HM 4; VDE 0250 part 215 HM5
BS 6724; BS 7655 section 6.1 LTS 2; CEI 20-11 M1; DIN EN 50363-8 TM7; DIN VDE 0276-604 HM4; DIN EN 50525-3-11 TM7; IEC 60092-360 SHF 1; NF C 32-323; VDE 0207 part 24 HM 2, HM 4; VDE 0250 part 215 HM5
Installation
Installation
Installation
Offshore/Shipbuilding
Offshore/Shipbuilding
Offshore/Shipbuilding
Mecoline
S TP 1006 F CHAR
1006
Halogen-free
TP
Sheathing
Flame retardant
CHAR
-25 to 80
9.2
47
D
195
41
1.55
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
Char‑forming
Char‑forming
Char‑forming
VDE 0207 part 24 HM 2; VDE 0250 part 215 HM 5; IEC 60092-360 SHF 1
VDE 0207 part 24 HM 2; VDE 0250 part 215 HM 5; IEC 60092-360 SHF 1
Installation
Installation
Installation
Mecoline
S TP 1021 F
1021
Halogen-free
TP
Sheathing
Flame retardant
-30 to 80
10.8
48
D
226
42
1.48
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, DIN EN 50525-3-11 TM7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, DIN EN 50525-3-11 TM7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
Installation
Installation
Installation
Offshore/Shipbuilding
Offshore/Shipbuilding
Offshore/Shipbuilding
Mecoline
S TP 1021 F CHAR
1021
Halogen-free
TP
Sheathing
Flame retardant
CHAR
-25 to 80
9.6
49
D
212
38
1.48
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
Char‑forming
Char‑forming
Char‑forming
DIN EN 50525-3-11 TM7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
DIN EN 50525-3-11 TM7, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
Installation
Installation
Installation
Mecoline
S TP 1028 F
1028
Halogen-free
TP
Sheathing
Flame retardant
-25 to 80
10.9
47
D
193
36
1.5
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
Installation
Installation
Installation
Offshore/Shipbuilding
Offshore/Shipbuilding
Offshore/Shipbuilding
Mecoline
S TP 1036 F
1036
Halogen-free
TP
Sheathing
Flame-retardant
-30 to 80
11
49
D
191
46
1.5
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 3, VDE 0207 part 24 HM2, VDE 0250 part 215 HM5, IEC 60092-360 SHF1
Installation
Installation
Installation
Mecoline
S TP 1040 F
1040
Halogen-free
TP
Sheathing
Flame-retardant
-30 to 90
15
49
D
550
27
1.34
Flame retardant
Flame retardant
Flame retardant
Halogen-free
Halogen-free
Halogen-free
Low smoke
Low smoke
Low smoke
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 2, BS 7655 part 6.1 LTS 3, BS 7655 part 6.1 LTS4, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4, IEC 60092-360 SHF1
BS 7655 part 6.1 LTS 1, BS 7655 part 6.1 LTS 2, BS 7655 part 6.1 LTS 3, BS 7655 part 6.1 LTS4, EN 50363-8 TM7, VDE 0207 part 24 HM2, VDE 0207 part 24 HM4, VDE 0250 part 215 HM5, VDE 0276 part 604 HM4, IEC 60092-360 SHF1
Installation
Installation
Installation
Melos code
PDF
Product group
Halogen
Shore hardness
LOI [%]
Density [g/cm³]
Mooney Viscosity
Tensile strength [N/mm²]
Elongation at break [%]
Base Polymer
Remarks
Process
Flame-retardant
Migration
FM
1224
1224
Soft
no
Not migration stabilised
Not flame-retardant
2-step
For XLPE insulation and HFFR sheathing
For XLPE/HFFR cables
Halogen free
50 A
1.84
45
1
≥ 250
IIR
Also suitable in combination with TPU and XLPE for flexible applications
2-step
Not migration stabilised
FM
989 BK
989
Medium
yes
Not migration stabilised
Not flame-retardant
Tandem
For XLPE insulation and HFFR sheathing
For XLPE/HFFR cables
Halogen free
75 A
1.91
55
≥ 0,5
≥ 20
IIR
Tandem
Not migration stabilised
FM
942
942
Medium
yes
Not migration stabilised
Not flame-retardant
2-step
For XLPE insulation and PVC sheathing
For XLPE/PVC cables
Halogen free
75 A
1.8
25
≥ 0,5
≥ 20
EPR
Temperature range -40°C to +60°C
2-step
Not migration stabilised
FM
1456
1456
Hard
no
Migration stabilised
Not flame-retardant
Tandem
For PVC insulation and PVC sheathing
For PVC/PVC cables
Halogen free
85 A
1.9
34
EPR
Tandem
Migration stabilised
FM
0553
553
Hard
no
Migration stabilised
Not flame-retardant
Tandem
For XLPE insulation and PVC sheathing
For XLPE/PVC cables
Halogen free
87 A
1.92
25
TPE-O
Tandem
Migration stabilised
FM
976
976
Medium
no
Migration stabilised
Flame-retardant
Tandem
For PVC insulation and PVC sheathing
For PVC/PVC cables
Halogen free
70 A
35
1.88
27
EPR
Flame retardant
Tandem
Migration stabilised
FM
1354/1
1354
Hard
no
Migration stabilised
Not flame-retardant
Tandem
For PVC insulation and PVC sheathing
For PVC/PVC cables
Halogen free
85 A
1.95
35
EPR
Tandem
Migration stabilised
FM
958
958
Medium
no
Migration stabilised
Not flame-retardant
Tandem
For PVC insulation and PVC sheathing
For PVC/PVC cables
Halogen free
75 A
1.95
25
EPR
Tandem
Migration stabilised
FM
0422/2
422
Hard
no
Migration stabilised
Not flame-retardant
Tandem
For PVC insulation and PVC sheathing
For PVC/PVC cables
Halogen free
85 A
1.96
27
EPR
Tandem
Migration stabilised
FM
908 BK
908
Soft
no
Migration stabilised
Not flame-retardant
Tandem
For PVC insulation and PVC sheathing
For PVC/PVC cables
Halogen free
65 A
1.86
22
EPR
For Ceander cables
Tandem
Migration stabilised
Load more ...

Cable compounds highlights

1
/
9